Kampek
040-502 9474Request quote →
Products

Products

Covalence brings heat-shrink technology to district heating, gas and oil. Stopaq is the self-healing corrosion protection for industry and water networks. BG Industry's heat-shrink joints go on pre-insulated pipes.

CovalenceStopaqBG Industry172 order codes
Category 1

Joint sealing

Covalence heat-shrink sleeves for district heating and gas pipes, BG Industry joint casings for pre-insulated pipes. Heat-shrunk or welded.

Seal for Life
Covalence
Heat-shrink technology for district heating joints

Choose this when the joint is on pre‑insulated pipe and the sizes vary: the sleeve is wrapped on site and covers casings from 90 to 1200 mm, including repairs and dimensions outside a standard series.

RJS-E · WPCP‑IV · FOPS‑100 · Perp Melt Stick · DHEC · CCS‑DHEC · S1113 sealing tape · TPSM · CPSM‑C30 · MPSM · WPC‑C30 · WPCT · Specialty products · HTLP60‑DCS · Dirax · S1301‑M epoksi · Flexclad‑II‑C30 · S1137 mastic filler tape · EN‑489:2009
Explore →
BG Industry
Heat-shrink joints for pre‑insulated pipes

Choose this when the pipe size falls in the DN 90–450 standard series and many similar joints are made: the prefabricated sleeve is fast and repeatable, available as heat‑shrink or electro‑weldable, and the joint is leak‑testable.

Shrink Sleeve · Reduction Sleeve · End Sleeve · PEX sleeve · Electro‑weldable sleeve · EN‑489‑1:2019
Explore →
Category 2

Corrosion protection

Stopaq, cold-applied visco-elastic protection for steel. Wire brushing to St 2 is enough, no blasting and no primer.

Seal for Life
Stopaq
Polyisobutene-based self‑healing corrosion protection

Choose this when the surface is bare steel or an irregular shape: bends, valves, flanges, tanks, and corrosion under insulation. ST2 cleaning is enough, no blasting is needed, and it works as prevention as much as repair.

Wrappingband · Casing Filler · Outerwrap · High Impact Shield · Outerglass Shield · ISO 21809‑3 · EN 12068 · NSF/ANSI 61
Explore →
Why it lasts

Comparison with a conventional coating

Traditional methodStopaq + Covalence
Coating recoated about every ten yearsLasts the service life of the pipe in the ground
Blasting and priming before applicationWire brushing to St 2 is enough, no primer
Coating cracks when the ground movesThe visco-elastic compound self-heals small defects
Can interfere with cathodic protectionCompatible with cathodic protection
Curing time before backfillingApplied cold, can be covered immediately
Applied with a torch or by blastingApplied cold, no torch

Figures from the Stopaq and Covalence manufacturer datasheets (Seal for Life).

Browse products by application too. Applications

Already know the code, or looking for an order reference? Product catalogue

Two jobs

Two jobs: joint sealing and corrosion protection

Damage almost always starts at the joint, or wherever the steel is left bare, whether the line carries district heating, gas or an industrial process.

Job 1: Joint sealing

Sealing the joint casing of pre‑insulated district heating and cooling pipes. The joint stays dry, and the insulation stays dry for the service life of the pipe.

Covalence · BG Industry
Job 2: Corrosion protection

Protecting buried and industrial lines against external corrosion. Self-healing protection for bare steel, applied cold without blasting.

Stopaq

What longer protection means for the network owner:

Longer service life lowers lifecycle cost
When a joint lasts in the ground for the service life of the pipe, that spot does not need to be dug up and recoated as often as a traditional coating.
Fewer maintenance shutdowns
Stopaq's self‑healing protection fills small defects by itself, so a single point of damage does not start corrosion under the coating or trigger an unplanned repair.
Faster installation on site
Stopaq is applied cold, with no blasting and no primer. Wire brushing to cleanliness grade St 2 is enough, and the work is feasible even in tight excavations.
The pipe can stay in service during the work
Stopaq's cold application without a torch means that on many sites the pipe can stay in service for the whole job.
Compatible with cathodic protection
Stopaq does not interfere with cathodic protection, so the coating and the cathodic protection work together on long buried transmission lines.
One supplier for the whole joint
You get Covalence, Stopaq and BG Industry from the same Tuusula warehouse. We match the right product combination to the site and deliver across Finland.

Request a quote

Briefly describe the application; we'll advise on the right product family.

CallRequest quote →